LiYY Electronic Control Cable
Application: To be installed in dry and humid rooms and used as a termination and
connection cable in the control, measuring and signal technology.
Construction: 1 ..... fine-stranded bare copper
2 ..... core insulation of polyvinylchloride (PVC)
3 ..... outer sheath of polyvinylchloride (PVC), grey
Information: Peak operating voltage [V]:
0,14 mm ... 350 Volt
all others ... 500 Volt
Test Voltage [VAC]:
0,14 mm ... 800 Volt
all others ... 1.200 Volt
Standards: adapted to DIN VDE 0812
DIN EN 60228 class 5 (construction)
DIN 47100 or factory standard (core identification)
Technical data:
Temperature range in motion -5°C till +50°C
fixed -30°C till +70°C
Bending radius in motion x diameter 10
Flammability standard EN 60332-1-2
Insulation resistance min. [MOhm/km] 100